# KASEEY (Yueqing Kaseey Electric Co., Ltd.) > Manufacturer and OEM/ODM supplier of passive electrical connection, comb busbar, copper/brass bar, terminal block, and DIN-rail distribution hardware (established 2007, Yueqing, Zhejiang, China). KASEEY manufactures passive electrical interconnection components for low-voltage distribution boards, switchgear assemblies, panel builders, wholesale distributors, and OEM/ODM programs. Core product lines include pin-type, fork-type, U-type, closed, and drawing-led custom comb busbars (standard pin/fork series across 8 to 16 mm2 and 50 to 80 A in 210, 1000, and 1016 mm lengths; extended M5.5 pin and M6 fork series up to 25 mm2 and 100 A), busbar end caps, tooth protective covers, feed-in connectors and insulated crimp terminals, wiring bridges, solid copper bars, N/PE brass bars, brass terminal blocks, terminal block boxes, pan assembly busbars, and 35 mm steel and aluminum DIN rails. Product scope boundary: KASEEY does not manufacture active switching or protective devices (MCBs, MCCBs, RCCBs, RCBOs, AFDDs, SPDs, contactors, relays, or ATS). Technical compliance documents (such as CE declarations, RoHS/REACH records, or UL standards-scope documentation) are verified and supplied per specific model number on inquiry (`sales@kaseey.com`). ## Company, Manufacturing & Compliance - [KASEEY Home](https://kaseey.com/): Company overview and passive electrical distribution hardware catalog. - [About KASEEY](https://kaseey.com/about): Yueqing Kaseey Electric Co., Ltd. background and production base in Yueqing Economic Development Zone, Zhejiang, China. - [Manufacturing](https://kaseey.com/manufacturing): Stamping, extrusion, assembly, and production capabilities for busbars and terminal hardware. - [OEM / ODM](https://kaseey.com/oem-odm): Custom pitch, tooth sequence, private labeling, marking, and repeat OEM/ODM supply programs. - [Quality Control](https://kaseey.com/quality-control): Dimensional inspection, material verification, and batch quality controls. - [Certifications](https://kaseey.com/certifications): Company-level compliance overview; model-specific test reports and declarations are confirmed per SKU. - [Downloads](https://kaseey.com/downloads): Catalogs and product reference documents. - [FAQ](https://kaseey.com/faq): General product, ordering, and OEM inquiry answers. - [Contact](https://kaseey.com/contact): Direct factory engineering and quotation contact (`sales@kaseey.com`). ## Solutions - [Modular Device Busbar Systems](https://kaseey.com/solutions/modular-device-busbar-systems): Pin, fork, and closed comb busbars matched to modular DIN-rail MCB, RCCB, and RCBO terminal platforms. - [Neutral & Earth Distribution](https://kaseey.com/solutions/neutral-earth-distribution): Segregated neutral (N) and protective earth (PE) brass bars and insulated screw-clamp terminal blocks. - [Panel & Pan Assembly Distribution](https://kaseey.com/solutions/panel-pan-assembly-distribution): Factory-assembled pan assembly busbars, solid copper bars, and enclosed distribution terminal block boxes. - [Custom Busbar OEM](https://kaseey.com/solutions/custom-busbar-oem): Drawing-led custom comb busbars, non-standard pole groupings, and private-label packaging for switchgear OEMs. ## Product Categories - [All Products](https://kaseey.com/products): Full KASEEY passive electrical interconnection product index. - [Comb Busbars](https://kaseey.com/busbars): Pin-type (P, S, C45, M5.5), fork-type (G, M6), closed, 1P to 4P, 1P+N, 3L+3N, and drawing-led custom comb busbars. - [Busbar End Caps](https://kaseey.com/busbar-end-caps): Insulating end caps (EK1-4, EK1-4E, EK3-10D) for cut open-channel and closed comb busbars. - [Busbar Protective Covers](https://kaseey.com/busbar-protective-covers): Snap-on insulating tooth covers (COV-1-2) for unused comb busbar pins and forks. - [Busbar Connectors & Terminals](https://kaseey.com/busbar-connectors): Feed-in busbar terminal connectors (TB25, TB50), insulated crimp terminals (FDD, PBDD, MDD, RV, SV, E, BDV, PTV), and cable ties. - [Wiring Bridges](https://kaseey.com/wiring-bridges): Preformed modular DIN-rail jumper bridges (WB2, WB3, WB4). - [Pan Assembly Busbars](https://kaseey.com/pan-assembly-busbars): Multi-pole panelboard pan assembly busbar interiors. - [Copper Bars](https://kaseey.com/copper-bars): Solid electrolytic copper busbars (KB series) for main and sub-distribution panels. - [Brass Bars](https://kaseey.com/brass-bars): Multi-hole neutral (N) and earth (PE) brass distribution strips (T15 series, 1-meter bars). - [Brass Terminal Blocks](https://kaseey.com/brass-terminal-blocks): Insulated screw-clamp brass N/PE terminal blocks (T001 to T010 series). - [Terminal Block Boxes](https://kaseey.com/terminal-block-boxes): Enclosed multi-pole panel distribution terminal block boxes. - [Steel & Aluminum DIN Rails](https://kaseey.com/steel-aluminum-din-rails): Slotted and unslotted 35 mm top-hat mounting rails in steel and aluminum. ## Representative Product References - [Pin Type 1-Phase Busbars P-1L](https://kaseey.com/busbars/pin-type-1-phase-busbars-p-1l): Standard pin-type comb busbar reference with published 8/10/13/16 mm2 (50/63/70/80 A) and 210/1000/1016 mm specification matrix. - [Fork Type 3-Phase Busbars M6](https://kaseey.com/busbars/fork-type-3-phase-busbars-m6): Extended fork-type 3-phase comb busbar family up to 25 mm2 and 100 A. - [Pin Type 1-Phase Busbars M5.5](https://kaseey.com/busbars/pin-type-1-phase-busbars-m5-5): Extended pin-type comb busbar family up to 25 mm2 and 100 A. - [Customized Busbars GV2](https://kaseey.com/busbars/customized-busbars-gv2): Drawing-led customized comb busbar reference confirmed by target device model and customer drawing. - [Busbar End Caps EK1-4](https://kaseey.com/busbar-end-caps/busbar-end-caps-ek1-4): Insulating end caps for 1P to 4P cut comb busbars. - [Busbar Connector TB25 / TB50](https://kaseey.com/busbar-connectors/busbar-connector-tb25-tb50): Main incoming feed-in terminal connectors for comb busbar rows. ## Technical Guides: Comb Busbar Sizing, Pitch & Installation - [How to Select an MCB Busbar](https://kaseey.com/blog/how-to-select-an-mcb-busbar): Step-by-step selection framework across pole configuration, terminal type, cross-section, and pitch. - [Pin-Type vs Fork-Type Busbars](https://kaseey.com/blog/pin-type-vs-fork-type-busbars): Terminal geometry, screw-head vs cage-clamp mating, and mechanical retention comparison. - [MCB Busbar Pitch Guide](https://kaseey.com/blog/mcb-busbar-pitch-guide): 17.8 mm vs 18 mm module pitch tolerance and cumulative alignment across long breaker rows. - [Comb Busbar Length and Module Count](https://kaseey.com/comb-busbar-length-module-count/): Pairing published module counts with finished millimeter lengths (210, 1000, 1016 mm) to prevent ordering errors. - [Comb Busbar Current Ratings: End-Feed vs Center-Feed](https://kaseey.com/comb-busbar-current-ratings-end-feed-centre-feed/): Current-split thermal math and feed-point sizing for modular rows. - [3L+3N vs 4P Comb Busbar](https://kaseey.com/3l3n-vs-4p-comb-busbar/): Tooth sequence and neutral routing differences for 1P+N RCBO and 4-pole breaker rows. - [C45 Comb Busbar Guide](https://kaseey.com/c45-comb-busbar/): C45 pin-type comb busbar geometry, plating, and modular device fit. - [How to Install a Comb Busbar](https://kaseey.com/how-to-install-a-comb-busbar/): Installation sequence, terminal seating, torque verification, and touch-safe finishing for MCB and RCBO rows. - [How to Cut a Comb Busbar](https://kaseey.com/how-to-cut-a-comb-busbar/): Safe field cutting, deburring, creepage restoration, and end-cap sealing. - [When to Replace a Comb Busbar](https://kaseey.com/when-to-replace-a-comb-busbar/): Condition-based inspection indicators for thermal discoloration, loose clamps, and insulation damage. - [Pan Assembly Busbar Ratings Explained](https://kaseey.com/pan-assembly-busbar-ratings-explained/): Reading 125 A and 250 A current ratings, connect-tab width, copper thickness, and IEC 61439-1/-3 assembly limits. - [Busbar Summation for Solar and Battery Backfeed](https://kaseey.com/busbar-summation-solar-battery-backfeed/): When an 80 A comb busbar is no longer enough under IEC 61439-3 Annex BB/CC and NEC 705.12 parallel backfeed. - [Mixing MCB Brands on One Comb Busbar](https://kaseey.com/mixing-mcb-brands-on-one-comb-busbar/): Three-axis X/Y/Z terminal datum mismatch, IEC 61439-3 / UL 67 verification limits, and compliant split-row or wiring-bridge alternatives. ## Technical Guides: Manufacturer, OEM & Compliance - [How to Choose a Comb Busbar Manufacturer](https://kaseey.com/how-to-choose-a-comb-busbar-manufacturer/): Factory evaluation criteria covering copper purity, stamping precision, insulation material, and quality control. - [Wholesale Comb Busbars](https://kaseey.com/wholesale-comb-busbars/): Factory-direct bulk sourcing checklist covering standard P-1L / M6 / C45 specs, packaging, quality verification, and OEM custom ordering. - [How to Qualify a Comb Busbar Supplier for OEM Supply](https://kaseey.com/how-to-qualify-a-comb-busbar-supplier-for-oem-supply/): Technical qualification stages, sample validation, and repeat-batch consistency checks. - [Busbar Factory vs Trading Company](https://kaseey.com/busbar-factory-vs-trading-company/): Verifying direct manufacturing capability versus intermediary resellers. - [Custom Comb Busbar Quote Guide](https://kaseey.com/custom-comb-busbar-quote/): Required inputs (target device model, drawing, pitch, phase sequence, cross-section, market) for custom quotations. - [MCB Busbar CE and UL Documentation](https://kaseey.com/mcb-busbar-ce-ul-documentation/): Distinguishing EU CE conformity declarations from North American UL standards scope and per-model documentation requests. ## Technical Guides: Accessories, Copper/Brass Bars & DIN Rails - [How to Select Busbar End Caps](https://kaseey.com/blog/how-to-select-busbar-end-caps): Matching insulating end caps to 1P to 4P and closed comb busbar profiles after cutting. - [Busbar Connectors Selection Guide](https://kaseey.com/blog/busbar-connectors-selection-guide): Selecting rated feed-in terminal connectors and insulated crimp terminals for main supply cables. - [Copper Bars vs Brass Bars for Electrical Panels](https://kaseey.com/copper-bars-vs-brass-bars-for-electrical-panels/): Conductivity, mechanical machinability, and N/PE vs main-feeder material selection. - [Brass Terminal Block Current Rating vs Wire Size](https://kaseey.com/brass-terminal-block-current-rating-vs-wire-size/): Matching conductor cross-section and screw-clamp capacity on N/PE brass terminal blocks. - [Steel vs Aluminum DIN Rails](https://kaseey.com/blog/steel-vs-aluminum-din-rails): Mechanical rigidity, corrosion resistance, and grounding considerations for 35 mm DIN rails.